The safety cabinet is the main isolation equipment used in the laboratory, which can prevent the diffusion of harmful suspended particulates, provide protection for the subjects, experiments and the environment, and safely apply to the operation of highly dangerous microorganisms, toxic substances and radioactive oligonucleotides.
1. Curtain isolating design to prevent internal and external cross contamination. (negative pressure type)
2. Move the glass door up and down, equipped with height limit alarm, so that the operator can use it correctly.
3. There is a special filter at the exhaust to control emission pollution.
4. Equipped with special waterproof socket to provide great convenience for the operator.
5. Controlled by LED LCD panel, it can effectively observe the size of the instrument downdraft and suction wind speed at any time.
6. The experimental area is made of stainless steel with high quality 304 stainless steel, and the working area is equipped with 2KW standby socket to provide convenience for the operator.
7. The isolation operating surface 10° tilt design, ergonomic, comfortable operation.
|
Model
|
BSC-1000A2
|
BSC-1300A2
|
BSC-1600A2
|
|
Overall size
|
1200×800×2120
(W×D×H)mm
|
1500×800×2120
(W×D×H)mm
|
1800×800×2120
(W×D×H)mm
|
|
Purification area size
|
1000×700×600
(W×D×H)mm
|
1300×700×600
(W×D×H)mm
|
1600×700×600
(W×D×H)mm
|
|
Purification efficiency
|
The 100 stage(America federal standard 209E)
|
|
Weight
|
160kg
|
180kg
|
200kg
|
|
Average air velocity
|
0.25-0.5m/s
|
|
Front inflow air
|
≥0.5m/s
|
|
Power
|
0.8KW
|
|
Average number of colonies
|
≤0.5(A/dish/hour)
|
|
Noise
|
≤65dB(A)
|
|
Vibration/half peak amplitude
|
≤3μm(X·Y·Z)
|
|
Power supply
|
220V 50HZ
|
|
Filter size
|
980×490×50
(L×W×H)mm
|
1280×490×50
(L×W×H)mm
|
1580×490×50
(L×W×H)mm
|
|
Outlet filter size
|
480*380*50
(L×W×H)mm
|
780*380*50
(L×W×H)mm
|
1080*380*50
(L×W×H)mm
|
|
Fluorescent lamp/UV lamp
|
21W×②/21W×①
|
28W×②/21W×①
|
28W×②/21W×①
|
|
Wind direction
|
Top φ300mm
|
|
Air tightness
|
99.99≤E≤99.999
|
|
illumination
|
≥700LX
|
Accept non-standard size orders from customers
product feature
|

|
1. Equipped with a new LED LCD panel; Can display instrument startup time and instrument running time; At the same time can display the downdraft and suction wind speed; And equipped with high efficiency filter replacement reminder function and UV lamp reservation timing on and off function.
|
|

|
2. Configure the domestic listed enterprise Yilida central air conditioning fan to ensure the stable air volume of the instrument.
|
|

|
3. Movable table and all stainless steel inner cavity, U-shaped surround design, to ensure that the experimental area table beautiful clean bright, not easy to rust, not easy to produce scratches; The table is made of diagonal slope, which can ensure the normal suction wind speed of the instrument without using the hand shelf, so as to solve the arm fatigue of the operator.
|
|

|
4. The operation area is equipped with 220V five-hole socket, which is convenient for the experimental personnel.
|
|

|
5. Integrated LED light stand and ultraviolet light stand are equipped in the operation area, which is convenient for the experimental personnel to plug and replace later.
|
|

|
6. The ultra-high efficiency filter used by the instrument is U15 level, and the double mesh is reinforced, which not only ensures the safety of the front and back filter paper but also greatly improves the strength of the high efficiency filter.
|
|
Model
|
BSC-1600A2
|
|
Overall size
|
1800×800×2120
(W×D×H)mm
|
|
Purification area size
|
1600×700×600
(W×D×H)mm
|
|
Purification efficiency
|
The 100 stage(America federal standard 209E)
|
|
Weight
|
200kg
|
|
Average air velocity
|
0.25-0.5m/s
|
|
Front inflow air
|
≥0.5m/s
|
|
Power
|
0.8KW
|
|
Average number of colonies
|
≤0.5(A/dish/hour)
|
|
Noise
|
≤65dB(A)
|
|
Vibration/half peak amplitude
|
≤3μm(X·Y·Z)
|
|
Power supply
|
220V 50HZ
|
|
Filter size
|
1580×490×50
(L×W×H)mm
|
|
Filter size
|
1080*380*50
(L×W×H)mm
|
|
Fluorescent lamp/UV lamp
|
28W×②/21W×①
|
|
Wind direction
|
Top φ300mm
|
|
Air tightness
|
99.99≤E≤99.999
|
|
illumination
|
≥700LX
|