一、product brief introduction
SCG-W5000 is a device that combines chemiluminescence technology and gel
imaging. It is equipped with a 9megapixel high-sensitivity refrigeration camera to
perform fast, accurate and high-throughput detection andimaging of samples. It is
widely used in life science, medicine, environmental protection and other fields
二、product feature
chemiluminescence system:
1, the band signal is weak, imaging at one time
2, the band signal is strong or weak, the effect diagram can be both
3, the source file is saved, the effect diagram can be adjusted at any time
gel imaging system:
1, three modes, a variety of parameters flexible adjustment, imaging clear and bright
2, UV laser protection plate, cutting glue is safe and convenient.
三、technical specification
|
Name of product
|
Multi-function imaging system
|
|
Model number of products
|
SCG-W5000
|
|
Dimensions of appearance
|
400×371×700 mm
|
|
camera
|
pixel
|
9 million
|
|
resolution
|
3000×3000
|
|
Size of pixel
|
3.76×3.76μm
|
|
Target surface dimension
|
1“(11.28×11.28 mm)
|
|
Full well charge
|
16.5ke-(HCG),50.5ke-(LCG)
|
|
sensitivity
|
877mv@1/30s
|
|
Read out noise
|
1.24e-(HCG),3.22e-(LCG)
|
|
Dark current
|
0.0003e-/s/pixel@-15℃
|
|
Signal noise ratio
|
42.2dB(HCG),47dB(LCG)
|
|
Time of exposure
|
0.1ms~1h
|
|
Binning mode
|
1×1,2×2,3×3
|
|
Scale of gray
|
16bit (65536 gray scale)
|
|
refrigeration
|
The relative environment was -40℃
|
|
Type
|
Black and white camera
|
|
lens
|
Aperture of light
|
F0.95-F16
|
|
Focal length
|
17mm
|
|
Type of
|
Power operated lens
|
|
Light source
|
Bright field light source
|
Falling LED white light source, symmetrical distribution on both sides
|
|
Ultraviolet light source
|
310-nm LED array with uniform transmission illumination
|
|
Dark box
|
Protection from light
|
Completely phototight, insulated from ambient light
|
|
Gate control
|
The gated sensor can control the bright-field light source switch
|
|
Turning table
|
Depending on the current mode, the filter is switched to match the chemiluminescence and gel application
|
|
Field of view
|
The effective field of view of the imprinted membrane was 136×136mm
The effective field of proteoglycan was 136×136mm
The effective field of view of nucleic acid gel was 140×140mm
|
|
Cut glue
|
After opening the door, the UV light source can be extracted and cut glue with the UV protection board
|
|
software function
|
Mode of exposure
|
High quality: Image quality is the highest
Criteria: Both image quality and exposure speed are considered
High sensitivity: the fastest exposure speed
|
|
Automatic exposure
|
Intelligent exposure technology can quickly determine the best exposure time, with time imaging and time accumulation functions, users can obtain the best image results with only one operation
|
|
Real time imaging
|
Real-time display of sample signal changes in the process of exposure, grasp every detail of the shooting, for the over-exposed area of the sample will add over-exposure display.
|
|
Time based imaging
|
After the exposure is completed, each frame of the exposure time can be generated. Through accurate backward adjustment, the user can select any frame of the exposure time as the final output result.
|
|
Accumulation of time
|
For the under-exposed sample, the user can also choose to continue the exposure after the exposure, so that the sample can get additional exposure effect on the basis of the exposure time.
|
|
PC Controller
|
10.4 inches, 1024×768,Windows operating system
|
|
External interface
|
USB 3.0×2
|
|
Operating voltage
|
100V-240V
|
|
Power of product
|
200W
|
|
Net weight of product
|
30Kg
|
notice:
1. It is forbidden to touch and scratch the lens lens inside the dark box with hands or sharp foreign objects;
2. After the experimental samples are placed, the instrument should be closed and the door should be turned down to avoid the external light entering the dark box and affecting the experimental results.
3. When conducting imaging experiments, it is forbidden to shake the experimental table or instrument, so as not to affect the quality of imaging;
4, pay attention to the safety of electricity, prohibit the experiment to pull the power cord and move the instrument;
5. After the experiment, the samples and experimental residues in the dark box should be cleaned.
四、Description of function body